Installation of Fire Protection Systems

Design, installation, testing and commissioning of various fire protection system as per NFPA standards and authority regulation. In order to undertake the process of designing a fire system for a building it is necessary to have a sound understanding of the relevant design standards and requirements of final authority for Fire and Safety in Oman. Our qualified engineering team is dedicated to take this challenge.

We offer the design, installation and Commissioning of:

  • Fire Fighting Systems
  • Fire Pump System
  • Automatic Sprinkler
  • Wet Riser system
  • Dry Riser system with Breaching inlet
  • Portable Fire Extinguishers and Fire Blankets
  • Special Fire Protection System
    •  Pre-action Fire Suppression system
    • Fire Suppression Systems
    • Clean Agent System – FM200
    • Clean Agent System – NOVEC

Installation of Fire Pump

Fire Pump unit is an assembled unit consisting of a Fire Pump, driver, controller, and accessories to provide water flow and pressure to systems dedicated for Fire protection. Installation of Fire pump system requires expert and experienced professionals. Our engineering and technical team are well organised and experienced in the selection, installation and commissioning of Fire Pump system as per NFPA 20.

We undertake the installation of various type of UL/FM approved Fire pumps of Capacity ranging from 50 gpm to 1500 gpm.

We are regularly involved in the following types of electric and diesel motor driven fire pump assembly installations:

* Split Case Horizontal

* Split Case Vertical

* Vertical Turbine

* End suction

Installation of Automatic Sprinkler System

Automatic sprinkler heads are individually heat activated and fixed into a piping network with water under pressure. When the heat of a fire raises the sprinkler temperature to its operating point, (a variety of temperature ratings, from 57 to 260 degrees) a liquid- filled glass bulb will shatter or a solder link will melt to open that single sprinkler, allowing water to discharge. The water is directed onto a diffuser or deflector which is designed to not only break the water into droplets of a specific size, but also to direct the spray to cover a specific floor and wall area.

We undertake the installation of Automatic Sprinkler system including pendent, upright and sidewall as per NFPA 13

Installation of Wet Riser System

Wet riser systems are pressurized with water having a permanent water supply from fire water pumps and fire water storage tanks. The wet riser system comprises of one or multiple vertical riser pipes or horizontal runs of piping that feed the Landing Valve connections. These risers are connected to fire pumps and fire water storage tanks located within the buildings.

A 25mm diameter for Hose Reel System OR 40 mm diameter for Hose Rack system AND, 65 mm diameter for the landing Valve tapping will be made from the wet riser in each floor level and fitted with multipurpose hoses and nozzles that are placed inside a cabinet, known as Class III hose systems, for the use of the Civil Defence department personnel or other trained fire fighting personnel.

In addition four way breeching inlets located at a ground level are connected to the bottom of the wet riser to pump water from the Civil Defence fire truck as supplementary water supply.

Installation of Dry Riser System

Dry riser systems are normally dry without a permanent fire pump or water connection to it and depend on the Civil Defence fire truck to pump water into the system.

Dry riser system comprises of one or multiple vertical riser pipes or horizontal runs of piping that are terminated to the two way breeching inlets located at ground level and connected to the 65mm diameter landing (Fire Department) valve outlets coupled or uncoupled with 65mm diameter, 30 m long, Civil Defence approved hose with multipurpose hose nozzle that are placed inside a cabinet for the use of Civil Defence Department personnel or other trained firefighting personnel.

Special Fire Protection System

Apart from the Automatic Sprinkler System and wet riser system, special fire protections systems are installing in specific hazards as per Civil Defence regulations.

  • Medium Velocity Water Spray System
  • Deluge Foam System
  • Pre-action System
  • Clean Agent System

Portable Fire Extinguishers are the best available first response to tackle the fire at its incipient stage. We supply all type of Fire Extinguishers of various capacities depends on the hazard classification and area as per ROP Fire & Life Safety code of practice and NFPA 10